Compression Ring
Fits your GSH25JSRFSS!
$11.80
Special Order
Fits your GSH25JSRFSS!
PartSelect Number
PS1015726
Manufacturer Part Number
WR02X12149
Manufactured by
GE
Part Videos
Replacing your General Electric Refrigerator Compression Ring
Troubleshooting
This part fixes the following symptoms:
Noisy | Fridge too warm | Freezer section too warm
This part works with the following products:
Refrigerator, Freezer.
This part works with the following products:
General Electric, Hotpoint, Kenmore.
Part# WR02X12149 replaces these:
AP3868937, 1169507, WR02X10509, WR02X10581, WR2X10509, WR2X10581
Customer Repair Stories
Average Repair Rating: 3.6 / 5.0, 26 reviews.
What's this?
- < Prev
- 1
- 2
- 3
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing installation instruction that matched.
My refrigerator began to overheat and the everything was thawing!!
My refrigerator began to overheat and the everything was thawing!! The condenser fan motor had seized and I thought this is something even I can replace.
I did a Google search on the refrigerator model number. The link to your site looked promising and I clicked on it. I was taken to your web page for my refrigerator and I clicked on the schematic for the condenser assembly.
The schematic had the parts I needed labeled clearly so this layman could be sure to get the right ones.
I ordered the parts at 12:45PM Monday and selected overnight shipping. The parts arrived at 8:35AM Tuesday (Thank you FedEx). I installed the parts and my refrigerator is up and running again.
To get to the condenser fan motor I took off the back panel on the fridge that covers the condenser, fan and coil. The fan/motor assembly is attached to a bracket I removed with two screws. Pulled the bracket assembly out of the back of the fridge, removed the fan blade and then the motor, and put the new motor on the bracket and stuck the new fan blade on the motor spindle. The trickiest part was getting the complete assembly back in. Just went slowly and took my time. Reconnected the wires, no problems. I took pictures of everything that I disassembled BEFORE I disassembled it in case I wasn't sure how something went back in but this job was so simple I didn't need the pictures.
I’m not sure how I could improve on this except maybe you could ship a refrigerator technician, too, to do the install.
Thank you PartSelect everything worked out better than I could have hoped and I saved $220.00 compared to what a repair service was quoting.
I did a Google search on the refrigerator model number. The link to your site looked promising and I clicked on it. I was taken to your web page for my refrigerator and I clicked on the schematic for the condenser assembly.
The schematic had the parts I needed labeled clearly so this layman could be sure to get the right ones.
I ordered the parts at 12:45PM Monday and selected overnight shipping. The parts arrived at 8:35AM Tuesday (Thank you FedEx). I installed the parts and my refrigerator is up and running again.
To get to the condenser fan motor I took off the back panel on the fridge that covers the condenser, fan and coil. The fan/motor assembly is attached to a bracket I removed with two screws. Pulled the bracket assembly out of the back of the fridge, removed the fan blade and then the motor, and put the new motor on the bracket and stuck the new fan blade on the motor spindle. The trickiest part was getting the complete assembly back in. Just went slowly and took my time. Reconnected the wires, no problems. I took pictures of everything that I disassembled BEFORE I disassembled it in case I wasn't sure how something went back in but this job was so simple I didn't need the pictures.
I’m not sure how I could improve on this except maybe you could ship a refrigerator technician, too, to do the install.
Thank you PartSelect everything worked out better than I could have hoped and I saved $220.00 compared to what a repair service was quoting.
Other Parts Used:
-
Jeffrey from Tampa, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
165 of 194 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I Placed A Heat Gun In The Freezer Section To Defrost The Coils And Did Not Return In Time. The Heat From The Heat Gun Rose Upward And Melted All Of The Soft Plastic Parts. The Good News Was That The 16 Parts Were Not Expensive But The One Main Part That Was Needed To Put It All Back Together Took 3
I replaced all of the plastic parts as well as the heat coil that is mounted at the bottom of the coils that keeps the coils from freezing up. If I had not melted the plastic parts the coil could have been replaced in 2 days, 1 day to receive the part and the next to do the work. This is the second time I have had to replace this heater.
Other Parts Used:
-
Guy from New Palestine, IN
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
63 of 113 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer and ice maker worked fine but bottom(cooler)did not cool innoff .Freezer compartment was also forming a lot of ice all over. l
Removed covers on the freezer compartment to gain access to the evaporator fan motor.The motor was turning but not fast innoff to move air true tthe evaporator coil.The evaporator fan it is the one that will cool the bottom and top of your refrigerator.
Other Parts Used:
-
Israel from Concord, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
62 of 94 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
High Pitch Noise from the Evaporartor Fan
Firt Removed the Ice Maker Tray and the full ice maker assembly. Removed the plastic shroud that sits over the fan assembly. Since the original connector (or the plug)for the motor had also a temperature sensor attached to it and did not know how to remove and trabsfer to the new motor connector I spliced the new motor to the old connector. It was fairly straight forward. Overall the job was not that difficult and since I was trying to be more meticulous it took a little longer. An average person can do it in around 30 to 45 minutes.
Other Parts Used:
-
Murtaza from E. Amhurst, NY
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set
53 of 78 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the evporator fan motor was noisy and ran constantly
First I removed the two plastic fan compartment covers mounted on the top of the freezer. Next I removed the ice maker by loosening the two bracket screws and unpluging the electrical connector. Be careful, I burned my hand on the heating element located on the bottom of the unit under the cube tray. I then removed the screws holding the back panel in place and pushed out the ice maker plug to remove the panel. I then removed the fan bracket screws and the electrical connector. Two screws hold the fan in place. I also replaced the two blue grommets, at the top and bottom of the fan module just to be safe. Installation was in the reverse. Note: this model apparently is hard on evaporator fans as this is the third one in four years!
Other Parts Used:
-
roger from st. ignace, MI
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
45 of 64 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evap Fan was sqeeling
First I removed the shelf and light cover, then removed 3 screws from the ice make. Then I removed 6 screws from the moter cover (back wall of the freezer) and removed it. I then removed the 2 screw holding the moter. This is where the soldering iron comes in. The wire leads from the old motor were molded into a 3" rubber holder and the end wire plastic connector held 6 prongs (2 from a thermo tube). The new motor only held the 4 moter prongs, 2 were empty. To resolve this problem I cut the wires on both the new and old motor. I then attached the old connector to the new moter with the soldering iron and shrink tubing. Replaced all the parts I had removed and started it up. Works like a champ.....
Other Parts Used:
-
David from Raleigh, NC
-
Difficulty Level:Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver
41 of 60 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
loud whinning noise of fan in freezer section
1. content of freezer was put in an ice box
2. panel covering rear of freezer compartment was removed, a few screws
3. old fan now accessible was removed an new fan mounted.
4. modular wiring plug broke, wires had to be soldered and wrapped in heat shrunk insulation
5. compartment was cleaned an rear inside panel closed
Thanks for all those who shared their experience and the schematics available on website. It gave me the confidence to to this myself. Its my second repair in freezer (previous being a defective heater)
2. panel covering rear of freezer compartment was removed, a few screws
3. old fan now accessible was removed an new fan mounted.
4. modular wiring plug broke, wires had to be soldered and wrapped in heat shrunk insulation
5. compartment was cleaned an rear inside panel closed
Thanks for all those who shared their experience and the schematics available on website. It gave me the confidence to to this myself. Its my second repair in freezer (previous being a defective heater)
Other Parts Used:
-
Daniel from MIAMI, FL
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
41 of 70 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy Evap Fan Motor
Could not haven been easier. Simply unplug fridge, remove air duct mounted on rear panel, release panel itself, pull fan blade off, disconnect grounding wire, detach fan motor bracket, disconnect wire harness to release fan motor, install new fan motor and reconnect, secure with bracket, reconnect grounding wire, reposition fan blade onto motor shaft, reinstall rear panel and secure screws. Remount air duct and plug appliance back in. VOILA. All done in less than 15 minutes!!!
Other Parts Used:
-
Vera from Alexandria, VA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
27 of 33 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The condensor fan in the unit appeared to have been chewed by a mouse and would not function and the lower door was too low.
The condensor fan in the unit appeared to have been chewed by a mouse and would not function. We had a service call to verify this and ordered the parts. Delivery was extremely quick and we were able to complete the repair and place the unit back into service within 2 hours.
All that was necessary was to remove the bottom cardboard cover, replace the fan and grommets, and replace the door bushings.
Thanks!!
All that was necessary was to remove the bottom cardboard cover, replace the fan and grommets, and replace the door bushings.
Thanks!!
Other Parts Used:
-
Eugene from Marion, TX
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers, Socket set
20 of 31 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor vibration
I pulled the inside cover in the freezer off, pulled the motor out of the bracket, replaced the fan blade , motor, and grommet and that was pretty much it. Very easy to replace. Parts select was fast and had the cheapest price available.
Thanks
Steven Roffey
Thanks
Steven Roffey
Other Parts Used:
-
Steven from Columbus, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
18 of 24 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
- < Prev
- 1
- 2
- 3
- Next >
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Rafeek
January 4, 2020
Evaporated fan making noise the shaft is loosen
For model number GTH17GBEDRBB
Hello Rafeek and thank you for writing.
The compression ring PS1015726 could be lost or faulty. You should also check the fan grommet PS963756. It is recommended to replace both parts at the same time. We hope this helps. Please contact us anytime.
Was this helpful?
Thank you for voting!
Related Parts:
- < Prev
- 1
- Next >
Related Parts
Model Cross Reference
This part works with the following models:
PartSelect Number: PS1015726
Manufacturer Part Number: WR02X12149
Manufacturer Part Number: WR02X12149
Brand
Model Number
Description